<%@ LANGUAGE = "VBScript" %> <% option Explicit %> <%response.Expires = 0%> <%response.buffer=true%> <% dim conn set conn = server.CreateObject("ADODB.Connection") conn.open "superloo" dim getnews, countnews, da da = 0 set getnews = conn.execute("SELECT * from news Order by order1 ASC;") set countnews = conn.execute("SELECT count(*) as count from news;") %> Superloo UK - Glossary

 

Glossary

Item
Options
Information
Unit Type
mains connected
Mains connected units are connected to both mains water and drainage. They operate like a standard wc with fresh water flush and discharge into a sewer or waste tank. Power is only needed for operation of lighting and or hot water / heating where available
 
self contained recirculating

 

Self contained recirculating units are chemical toilets with a holding tank underneath. They use electric pumps to filter and pump the liquid around the system and all toilet waste is collected in the central holding tank. These units require power to operate and where possible should also be connected to water to fill basin tanks.


 
hand pump self contained trailer

 

Self contained hand pump units operate in the same manner as recirculating units except that the flushing mechanism is hand pump operated instead of electric. No services are required for this type of unit although power for lighting is optional.


 
hand pump - single unit

 

Single hand pump units for sites have a 45 gallon holding tank with a hand pump flush mechanism. This recirculates the water and chemical around the wc. Single units require no services to operate.


 
straight drop

 

Straight drop chemical toilets are the most basic with no flush mechanism. They require no services to operate.


 
Shower

 

Shower units are mains connected and will need both water and waste connection to either a tank or mains sewer. Power is needed for lighting only as the units are all gas operated (using propane bottles)


 
Other
 

Configuration
Ladies

 

Units are either available as an all ladies, all gents or Dual unit - ie with ladies at one end and gents at the other. Where the unit is specified as 'Ladies / Gents or Dual' the unit can be configured as any of these options. The final option is unisex where the configuration of the unit is not specified. These can be used in any configuration you want.


 
Gents
 
 
Dual
 
 
Unisex
 

Facilities provided
Unisex WC's
 
 
Unisex basins
 
 
Ladies WC's

 

Where units are available as either Ladies / Gents or Dual units we have only specified the number of facilities available when using the unit as a Dual unit.


 
Ladies basins
 
 
basin type

 

Basins are either Vanity or wall mounted. Vanity units are inset into cupboards and generally of a higher standard with the pipework enclosed. Wall mounted basins are generally smaller and attached to the wall with all pipework exposed beneath.


 
Gents WC's
 
 
Gents Urinals
 
 
Gents basins
 
 
basin type
 

Specifications

 
heating
no

 

Some units are equipped with interior space heating for winter use, which will need an adequate power supply to operate

.

 
yes - electric
 
 
 
hot water
no

 

Hot water is available in some units. This can be either gas (using propane bottles), or electric. Where electric hot water is supplied an adequate power supply is required. It is essential that an external water supply is provided when hot water is required.

 

 
yes - gas
 
 
yes - electric
 

standard
VIP

 

VIP units are the top of the range, although there are various different qualities of unit within this genre. VIP units generally have the following features:
Carpets or floor tiles, wooden toilet seats, vanity basins, higher quality fittings such as taps, mirrors basins etc, Most VIP units have superior lighting, pictures on the walls, air fresheners and better quality wall coverings.


 
Deluxe

 

Deluxe units are high quality public or new units. They are generally fitted with vinyl floors, wall mounted basins and a more basic finish than a VIP unit.


 
Standard

 

Standard units are public quality event equipment


 
Basic

 

Basic units are the cheaper end of the market with none of the frills of the other units.


 
Site

 

Site units are only suitable for buidling sites.



Dimensions approx
Length

 

Dimensions are all in feet / inches and are approximate. When working out access please allow for a towing vehicle and note that the dimensions shown do not include small items such as door furniture which protrude from the unit. Generally we request that a minimum of 6 inches either side is acceptable. When the unit is in position please allow for steps and access into the unit.


 
Width
 
 
Height
 
 
towbar
 

Suitability
recommended for

 

The units can be used for any purpose you wish however the smaller units have limitations not just in the number of facilities, but in the case of self contained units, in the capacity of the tanks. We have therefore included guidelines as to how many people the units are suitable for and the maximum we feel that should be using one unit. Please note this is based on private events not larger events where you can hire less units for more people.


 
maximum usage
 

Services required
Water

 

This section covers what services the units require. Please note that although units require some services to work, we can of course supply water tanks, bowsers, pumps and generators where those services are not available. It is also possible to work around a lack of services in other ways - please call for advice


 
power
 
 
drainage
 
 
Home | News | Our Range | Find Us | Contact Us | John Anderson Hire | Superloo | Greater London Conveniences